神马电影_午夜神马_午夜电影_神马午夜_欧美日韩中文字幕_欧美日韩在线播放_欧美日韩精品_中文字幕观看_欧美日韩中文字幕_欧美中文字幕视频_欧美日韩精品_欧美成人在线视频_欧美乱人伦中文字幕在线不卡_日韩免费高清专区_久久久久亚州?Ⅴ无码专区首_精品国偷自产在线不卡短视频_尹人久久大香找蕉综合影院中文字幕免费在线观看_欧美激情综合色综合啪啪五月

您好,歡迎來到歐亞貿易網!請 |免費注冊

產品展廳本站服務收藏該商鋪

鵬鑫(泉州)貿易有限公司

免費會員
手機逛
15059812725
鵬鑫(泉州)貿易有限公司
當前位置:鵬鑫(泉州)貿易有限公司>>開關>>撥動開關>> 無油開關PRG-PSWHITLOCK-DNFT無油開關PRG-PS

WHITLOCK-DNFT無油開關PRG-PS

產品二維碼
參  考  價:面議
具體成交價以合同協議為準
  • 產品型號:無油開關PRG-PS
  • 品牌:
  • 產品類別:撥動開關
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2023-07-07 21:24:13
  • 瀏覽次數:18
收藏
舉報

聯系我時,請告知來自 歐亞貿易網

鵬鑫(泉州)貿易有限公司

其他

  • 經營模式:其他
  • 商鋪產品:985條
  • 所在地區:
  • 注冊時間:2023-07-07
  • 最近登錄:2023-07-07
  • 聯系人:蔣艷萍
  • 電    話:15059812725
產品簡介

詳情介紹

WHITLOCK-DNFT無油開關PRG-PS




The DNFTs come in three models to switch voltages up to 240 VDC:

LED model
LCC model
PRG model


產品選型資料下載:

· DNFT-PRG


· DNFT-LCC
· DNFT-LED
· DNFT-LED-PS
· DNFT-PRG-PS (Programmable)
· DNFT-PRG (Standard, Programmable)
DNFT-PRG-PS (Programmable w/ PS Option)
DNFT-LCC 45 Second Alarm
DNFT-LCC 2 Minute Alarm
DNFT-LCC 3 Minute Alarm
DNFT-LCC 4 Minute 15 Second Alarm
DNFT-LED
DNFT-LED-PS


Digital No-Flow Timer (DNFT)

Premier Digital No-Flow Timer (DNFT)無油流開關產品介紹:

Monitors Movement of Divider Valve Piston 監測分配器柱塞的運動
Closed Loop or Open Loop Operation 開式或閉式回路 Installs Directly to Divider Valve 直接安裝在分配器上面
Not Affected By Temperature or Viscosity 不受溫度和粘度的影響
Requires No External Power 不需要外接電源
LED or LCC Cycle Indicator 帶LED或LCC循環指示
Dependable “Timed" Shutdown Protection 可靠的停機保護
Explosion Proof Rated for 防爆等級:
Class 1, Division 1, Groups A,B,C,D CSA Approved 通過CSA防爆認證 CE Approved 和CE防爆認證


SPECIFICATIONS :

Material Stainless Steel, Aluminum
Temperature Range -40 F to +185 F
Switch Rating 2.5VA/240 VDC
Epoxy Encapsulated UL LISTED EL-CAST VFR 641
Alarm/Shutdown Factory default for 2 minute alarm
Power Field Replaceable -Lithium Battery
Battery P/N 000505
Alternate Battery Radio Shack 960-0418
Divider Block Application Dropsa/Lincoln/SBCO/Lubriquip
Warranty 2.5 Years


WHITLOCK DIGITAL NO-FLOW TIMER
506LIT LED-WI-1
DNFT
WHITLOCK INSTRUMENT

07.11.01

1300 N. Texas Odessa, TX 79761
R

915.3373412 Fax 915.335.5926
DIGITAL NO-FLOW TIMER
1.800.337.3412 INSTRUMENT

U.S. PAT. NO. 5,835,372 WHITLOCK
ODESSA, TX USA
DNFT-LED
P/N: 000506

MODEL Factory Sealed RATED 2.5VA / 240VDC

R
II 2G EEx m IIB T5 CE SERIAL #
C US ClI;Zone1;ExmdIICT4 000506
ClI;Div1;Grps.A,B,C,D;T4 ALARM 2-MIN

186200 0344 P/N
KEMA 00ATEX1090 X Amb. -40° C +85°C
RED-Open Loop ORANGE-Closed Loop GRN-Ground
DNFT-LED
MONITORS MOVEMENT OF DIVIDER
VALVE PISTON FOR DEPENDABLE
"TIMED" SHUTDOWN PROTECTION

CLOSED LOOP OR OPEN LOOP OPERATION INSTALLS DIRECTLY TO DIVIDER VALVE
NOT AFFECTED BY TEMPERATUREOR OIL VISCOSITY
REQUIRES NO EXTERNAL POWER
LED INDICATOR -CYCLE INDICATION
DEDICATED SWITCH CLOSURE TO MONITOR EACH DIVIDER VALVE CYCLE (PS OPTION)
FIELD REPLACEABLE BATTERY
186200 Cl I; Div 1; Grps. A,B,C,D;T4

KEMA 00ATEX1090
X Amb.
-40° C +85°C


DESCRIPTION
The DNFT-LED is a totally enclosed electronic device, combining the latest technology in microprocessor and transistor components for detecting Slow-Flow and No-Flow of divider block lubrication systems. The DNFT incorporates an oscillating crystal to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability. The magnet assembly and control housing mount directly to the divider valve to become an integral part of the lubrication system. The DNFT operates on a field replaceable lithium battery. If battery voltage drops below normal operating levels, the DNFT goes into alarm mode and the unit cannot be restarted. LED models utilize an LED to indicate each cycle of the divider valve. This enables the operator to easily set and monitor lubrication rates.
OPERATION
Lubricant flow through the divider valve assembly forces the pistons to cycle back and forth causing a lateral movement of a magnet linked to the piston. Movement is monitored by the microprocessor which resets the timer, lights the LED, and allows the unit to continue operation, this indicates one complete cycle of the lubrication system. The microprocessor must receive this cycle in a predetermined time or a shutdown will occur. The DNFT will automatically reset alarm circuit when normal operation of divider valve resumes.

WHITLOCK
506LIT LED-WI-2

DNFT WHITLOCK INSTRUMENT

DIGITAL NO-FLOW TIMER INSTRUMENT P/N 000506 DNFT-TO-LED DIGITAL NO-FLOW TIMER INSTALLS ON DROPSA/LINCOLN/SBCO/LUBRIQUIP DIVIDER
BLOCK. SWITCH RATING 2.5VA 240VDC

1. Loosen all Allen head set screws (A) on DNFT (B) and remove magnet housing (C). Do not remove magnet, spring or spacer from magnet housing.

2. Remove piston enclosure plug (D) from end of divider valve where DNFT will be installed. The DNFT does not have to be installed on the top divider valve. It may be installed on any convenient divider valve, top to bottom. (Notice:Do not install DNFT on Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.)

3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C). Screw magnet housing (C) into end of divider valve (E). Torque to 15 foot pounds max.

4. Slide DNFT (B) all the way onto hex of magnet housing (C). Tighten set screws on hex of magnet housing. Torque 25 inch pounds max.

5. The LED on the DNFT indicates each divider valve cycle. This enables operator to adjust the lubricator pump for correct cycle time and oil consumption recommended by compressor manufacturer. If LED does not blink with compressor running or by manually pumping oil into divider valve, the DNFT must be adjusted. Normal cycle indication is a bright strobe type blink.

6. Before adjusting DNFT, divider valve must be cycling. This can be achieved with the compressor running or by manually pumping oil through the divider valve assembly with a hand priming pump.

7. Adjustment is made by sliding the DNFT (B) all the way on the hex of the magnet housing (C). Tighten set screws on hex of the magnet housing to 25 inch pounds max. Check for LED blink to confirm correct adjustment. If LED does not blink with divider valve cycling, adjust the DNFT back in 1/16" increments. Correct adjustment of the DNFT is confirmed by blinking LED.

8. All conduit and connections should be appropriate for area classification. Notice: Conduit and fittings must be supported to avoid bending magnet housing.

9. After installing magnet assembly and pre-compressor start-up, it is absolutely necessary to purge all air from dividerblock lubrication system. This can easily be accomplished with a lubrication system purge gun.
10.DNFT must be installed with correct magnet assembly for each divider valve manufacturer.
Lincoln-7/16"-20 extended nose with O- ring Dropsa
Trabon-1994 or earlier 7/16"-20 with metal crush gasket SBCO &Trabon-1995 and later 7/16"-20 with O-ring
Notice: When installing more than one DNFT, each DNFT must be wired to a separate alarm circuit of the control panel, annunciator or PLC to simplify troubleshooting the lubrication system and DNFT.
O-RING OR ALLEN HEAD
INTERNALVIEWOF DIVIDERVALVE METAL GASKET (F) DNFT (B) MAGNET HOUSING SPACER SET SCREWS(2) (A) SPRING #22AWG18"LEADS(7)(I)
(E) (C)
WHITLOCK
RED

DIGITALNO-FLOWTIMER
RED GREENINSTRUMENT

GREEN
ORANGE
ORANGE

CYCLEINDICATIONODESSA,TXUSA
MODEL LED
ORANGE
RATED 2.5VA / 240VDC



上一篇: RTD\GAUMER\RTD-5-72SD