| 維氏硬度計 壓痕測量的**允許誤差 |
| | 維氏壓痕測量裝置 的分辨力與**允許誤差 壓痕對角線長度d/mm | 測量裝置的分辨力 | **允許誤差 | d≤0.040 | 0.2um | ±0.4um | d>0.040 | 0.5%d | ±0.8%d |
維氏硬度計 示值的**允許誤差 硬度符號 | 硬度計示值的**允許誤差(±%) | | 硬度,HV | | 50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 | 700 | 800 | 900 | 1000 | | HV0.05 | 6 | 8 | 9 | 10 | | | | | | | | | | | | | HV0.1 | 5 | 6 | 7 | 8 | 8 | 9 | 10 | 10 | 11 | | | | | | | | HV0.2 | | 4 | | 6 | | 8 | | 9 | | 10 | 11 | 11 | 12 | 12 | | | HV0.3 | | 4 | | 5 | | 6 | | 7 | | 8 | 9 | 10 | 10 | 11 | 11 | | HV0.5 | | 3 | | 5 | | 5 | | 6 | | 6 | 7 | 7 | 8 | 8 | 9 | | HV1 | | 3 | | 4 | | 4 | | 4 | | 5 | 5 | 5 | 6 | 6 | 6 | | HV2 | | 3 | | 3 | | 3 | | 4 | | 4 | 4 | 4 | 4 | 5 | 5 | | HV3 | | 3 | | 3 | | 3 | | 3 | | 3 | 4 | 4 | 4 | 4 | 4 | | HV5 | | 3 | | 3 | | 3 | | 3 | | 3 | 3 | 3 | 3 | 3 | 4 | | HV10 | | 3 | | 3 | | 3 | | 3 | | 3 | 3 | 3 | 3 | 3 | 3 | | HV20 | | 3 | | 3 | | 3 | | 3 | | 3 | 3 | 3 | 3 | 3 | 3 | | HV30 | | 3 | | 3 | | 2 | | 2 | | 2 | 2 | 2 | 2 | 2 | 2 | | HV50 | | 3 | | 3 | | 2 | | 2 | | 2 | 2 | 2 | 2 | 2 | 2 | | HV100 | | | | 3 | | 2 | | 2 | | 2 | 2 | 2 | 2 | 2 | 2 | | 注: 1.壓痕對角線長度小于0.02mm時,表中未給出值. 2.對于中間值,**允許誤差可通過內插法求得. 3.表中有關 顯微硬度計 的值以0.001mm或壓痕對角線長度平均值2%為**允許誤差給出的.比較大者為準. | | | | | | | |
維氏硬度計 的示值重復性 標準塊的硬度范圍 | 示值重復性(%) | HV5~HV100 | HV0.2~<HV5 | <HV0.2 | ≤225HV | ≤6.0 | ≤12.0 | ≤12.0 | >225HV | ≤4.0 | ≤8.0 | ≤10.0 |
|
版權與免責聲明:
1.凡本網(wǎng)注明"來源:歐亞貿易網(wǎng)"的所有作品,版權均屬于歐亞貿易網(wǎng),轉載請必須注明歐亞貿易網(wǎng)。違反者本網(wǎng)將追究相關法律責任。
2.企業(yè)發(fā)布的公司新聞、技術文章、資料下載等內容,如涉及侵權、違規(guī)遭投訴的,一律由發(fā)布企業(yè)自行承擔責任,本網(wǎng)有權刪除內容并追溯責任。
3.本網(wǎng)轉載并注明自其它來源的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點或證實其內容的真實性,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網(wǎng)站或個人從本網(wǎng)轉載時,必須保留本網(wǎng)注明的作品來源,并自負版權等法律責任。
4.如涉及作品內容、版權等問題,請在作品發(fā)表之日起一周內與本網(wǎng)聯(lián)系。